All products
%
Heidolph Viton® Tubing, id: 6.4mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
Compare
%
Nabertherm L 15/12/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type S (1200 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With flap door (L)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-25
Tray with fixed clamps F-25 To load 153 Erlenmeyer flasks with a volume of 25 ml
Compare
%
Heidolph Viton® Tubing, id: 7.9mm - wt: 2.5mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
Compare
%
Ohaus Rotor Angle 4x500ml ID
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter 1x250ml D60.5mm FA x2 (30559416)); Adapter 1x175/225 ml D61.5mm FA x2 (30559417); Adapter 1x50ml D29.5mm FA x2 (30559419); Adapter 3x50ml D29mm RB x2 (30559420); Adapter 4x30ml D25.5mm RB x2 (30559421); Adapter 6x15ml D17mm FA x2 (30559422); Adapter 1x250ml D61.5mm FB x2 (30564850)
Compare
%
Vacuubrand chemistry diaphragm pump MD 1C
Three-stage chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors and meet high requirements regarding ultimate vacuum. The three-stage construction provides the advantageous combination of high pumping speed and deep ultimate vacuum in a pump with a very small footprint. All parts in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms increase reliability and extend operating life. The MD 1C with gas ballast valve is optimally prepared for pumping easily condensable vapors (high boiling solvents).
Performance features
• outstanding chemical resistance and superior vapor tolerance
• exceptionally high performance even at low vacuum
• excellent ultimate vacuum even with gas ballast
• whisper quiet and ultra low vibration
• proven long diaphragm life, maintenance-free drive system
Compare
%
Heidolph Viton® Tubing, id: 0.8mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
Compare
%
Nabertherm LT 24/11/B510 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation B510 (5 programs with each 4 segments)
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Ohaus Rotor Angle 45° 24x1.5/2.0ml ID BIOSEALS
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
Compare
%
Kühner Tray with fixed clamps F-50
Tray with fixed clamps F-50 To load 100 Erlenmeyer flasks with a volume of 50 ml
Compare
%
Heidolph Viton® Tubing, id: 1.7mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
Compare
%
Vacuubrand chemistry vacuum system MD 1C +AK+EK
This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors. This system is usable for increased vacuum requirements with high boiling solvents and often replaces rotary vane pumps. Typical applications are rotary evaporators and vacuum drying ovens. The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets. The waste vapor condenser at the outlet (EK) is highly efficient and compact. The condenser enables near-100-percent solvent recovery, efficient recycling and active protection of the environment.
Performance features
• outstanding chemical resistance and superior vapor tolerance
• exceptionally high performance even at low vacuum
• excellent ultimate vacuum even with gas ballast
• whisper quiet and ultra low vibration
• excellent environmental friendliness due to efficient solvent recovery
Compare
%
Heidolph Viton® Tubing, id: 3.1mm - wt: 1.6mm
For Single- and Multi-Channel use (not suitable with cassette small)
• Application: Excellent acid resistance at high temperatures
Features:
• Low gas permeability
• Resistant to solvents and corrosives at high temperatures
• Material: Fluorocarbon rubber, thermoformed Viton® B (67% fluorinated); opaque black
• Complies with the standards: GLP conform
• Temperature range: -30 to +205 °C
• Sterilization: Sterilization is not recommended
• Restriction: Limited performance life
Compare
%
Binder CB 56 CO₂ incubator
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is also suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive range of options and accessories.
PRODUCT BENEFITS
• Safe – cell cultures receive maximum protection against contamination
• Reliable – constant, stable conditions for cell well-being
• Smart – simple routine cleaning and convenient operation
• Economical – efficient operation without consumables
PRODUCT FEATURES
• Optimized humidification system with condensation protection
• Proven anti-contamination concept with 180 °C hot-air sterilization
• Hot-air sterilizable CO₂ sensor with single-beam infrared technology
• Seamless stainless-steel inner chamber with flanges as shelf support system
• 2 perforated shelf
• Fanless interior with Venturi CO₂ gas mixing nozzle
• Intuitive touchscreen controller
• Internal data recording, readable in open format via USB interface
• Fault diagnosis system with visual and acoustic alarm
• Interfaces: Ethernet, USB, zero-voltage alarm contact
• Fail-safe CO₂ system for protecting the pH of cell cultures
Compare
%
Nabertherm LT 24/11/C550 muffle furnace
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability.
Standard Equipment
• Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
• Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
• Thermocouple type N (1100 °C)
• Ceramic heating plates with integral heating element which is safeguarded and easy to replace
• With lift door (LT)
• Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
• Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
• Adjustable air inlet integrated in door (see illustration)
• Exhaust air outlet in rear wall of furnace
• Controller with touch operation C550
• Solid state relays provide for lownoise operation
Option
• Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
• Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
• Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
• Manual or automatic gas supply system
• Port for thermocouple in the rear wall or in the furnace door
Compare
%
Kühner Tray with fixed clamps F-100
Tray with fixed clamps F-100 To load 74 Erlenmeyer flasks with a volume of 100 ml
Compare
%
Heidolph Tygon® Two-Stop Tubing, id: 0.5mm - wt: 0.9mm
Two-stop tubing (40 cm) for Cassette small
• Application: For standard applications
Features:
• Non-toxic, non-oxidizing
• Good resistance to acids, bases and inorganic media
• Very low gas permeability, good performance life
• Material: Thermoplastic soft PVC, transparent
• Complies with the standards: FDA (21 CFR 177.2601) and GLP
• Temperature range: -50 to +75 °C
• Sterilization: Can be autoclaved for 30 min at 1 bar and 120 °C (material may change color) or with ethylene oxide
• Restriction: Segregation of plasticizers is possible
Compare
%
Ohaus Rotor Angle 24x1.5/2.0ml BIOSEALS V2
Frontier rotors extend the functionality of Frontier centrifuges by increasing the number of tubes of varied types and sizes that can be used in conjunction with each of the centrifuge models. Easy to clean and operate, the rotors are durably constructed to withstand demanding centrifugation.
Compatible adapters and other accessories:
• Adapter, D6mm, 0.2/0.4ml Tubes x6 (30130884); Adapter, D8mm, 0.5ml Tubes x6 (30130885)
Compare
%
Vacuubrand chemistry diaphragm pump MD 4C EX
ATEX chemistry diaphragm pumps offer all advantages of oil-free chemistry diaphragm pumps. Typical applications are rotary evaporators and drying ovens with potentially explosive atmospheres. The ATEX approval includes the interior of the pump (in contact with pumped gases) as well as the surrounding area of the pump. All wetted parts of the pumps have excellent chemical resistance and are mainly made of antistatic materials. Included in delivery is a separate gas ballast connection part for use of inert gas.
Performance features
• outstanding chemical resistance and superior vapor tolerance
• flame proof motor with integrated, self-locking overload and excess temperature protection for direct 230V / 50Hz single phase power supply. No need for any additional and specific overcurrent protection device
• overpressure safety relief valves internally and at outlet
• safety diaphragm technology with option for inert gas purge and detection of diaphragm breakage
Compare
%
Binder CB 170 CO₂ incubator
The BINDER CB series CO₂ incubators represent the premium class among CO₂ incubators. They are suitable for all sensitive incubation applications and provide optimal conditions for cell growth. CB series incubators are also ideal for complex cultivation experiments and for creating individual environmental conditions.
PRODUCT BENEFITS
• Safe – cell cultures receive maximum protection against contamination
• Reliable – constant, stable conditions for cell well-being
• Smart – simple routine cleaning and convenient operation
• Economical – efficient operation without consumables
PRODUCT FEATURES
• Optimized double-pan humidification system with condensation protection
• Proven anti-contamination concept with 180 °C hot-air sterilization
• Hot-air sterilizable CO₂ sensor with single-beam infrared technology
• Seamless stainless-steel inner chamber with flanges as shelf support system
• 3 perforated shelf
• Fanless interior with Venturi CO₂ gas mixing nozzle
Compare